Cat 2000 Plus Automated Chemical Controller - Model P2000
THE WATER QUALITY SOLUTION FOR DEMANDING APPLICATIONS
The CAT 2000 PLUS programmable water chemistry controller has been designed to accommodate demanding applications which benefit from precise control over a wide range of operating parameters. Adaptability makes the PLUS an excellent choice for zoological, aquaculture and water treatment facilities as well as swimming pools and spas that wish to track derived chlorine or bromine residuals in parts per million.
The PLUS combines the powerful simplicity of the CAT 2000 with a host of adaptable programmable features for unmatched precision in water quality management. During setup, the PLUS allows simple configuration of the following:
- ORP or PPM based control and display.
- Programmable independent overfeed timers.
- Programmable Setpoint and Alarm Ranges.
- Proportional or Direct Chemical dosing.
- Selectable pH Priority Feed.
Powerful, affordable and incredibly simple to install and operate, the CAT 2000 PLUS delivers sparkling, precise water balance in the toughest applications. The CAT 2000 PLUS is compatible with existing chemical feeding equipment, and is shipped complete with sensors, installation hardware, and a comprehensive installation and operation guide.
CAT 2000 PLUS CONTROLLER SPECIFICATIONS | |
Display Range: | ' |
pH | 4.0 - 9.99 |
ORP | 0 - 999MV |
PPM Active Sanitizer | 0.0 - 6.0 PPM |
Display Resolution: | ' |
pH | 0.1 pH |
ORP | 1.0 MV |
PPM Active Sanitizer | 0.1 PPM |
Setpoint Range: | why |
pH | 7.0 - 8.0 |
ORP | 200 - 995 MV |
PPM Active Sanitizer | 0.2 - 4.0 PPM |
Control Accuracy: | Cool |
pH | +/- 0.1 pH |
ORP | +/- 1.0 MV |
PPM Active Sanitizer | +/- 0.1 PPM |
Dispensing Method: | ' |
pH | Proportional or Direct Feed |
ORP / PPM | Proportional or Direct Feed |
Dosing Options: | ' |
pH | Priority Feed |
ORP / PPM | ORP or PPM Based Feed |
Mode Selections: | Cool |
pH | Automatic Feed / Off / Manual Feed |
ORP | Automatic Feed / Off / Manual Feed |
pH Feed | Acid or Base Feed |
pH Mode | Auto / Set / Calibrate |
ORP Mode | Auto / Set |
PPM Mode | Auto / Set / Calibrate |
Safety Systems: | Safe |
pH | Audible / Visual Safeguard Alarms Programmable Overfeed Timer Priority Feed Programmable Setpoint & Alarm Ranges |
ORP | Audible / Visual Safeguard Alarms Programmable Overfeed Timer Programmable Setpoint & Alarm Ranges |
Controller Unit | Comprehensive Diagnostic Self-Test Self-Calibrating Electronics 3 Stage Over-UnderVoltage Protection Remote Alarm Output |
Optional | Rotary or Pressure Flow Sensor |
Outputs: | Cool Choices |
pH Feed | 10 Amp/120 VAC Pigtail or 24 Volt (Solenoid Valve) |
ORP Feed | 10 Amp/120 VAC Pigtail or 24 Volt (solenoid Valve) |
Remote Alarm | 12 Volt DC |
Flow Sensor | Auto-Detect |
Optional Equipment: | Cool ' |
| Rotary or Pressure-based Flow Sensor |
| Machined Acrylic Flow Cell Assembly |
| DataCAT Communications Package |
| RS232 Computer Interface |
| Serial Printer / Recorder |
| External Modem |
Export Options | Factory Configured for Power Sources World-Wide |